Lab Animal Equipment
Lab Animal Equipment
  • Step Down Test
  • Step Down Test
  • Step Down Test
  • Step Down Test

Step-Down Avoidance Task

The Rodent Step-Down Avoidance Task is widely used in observing the effects of drugs on memory and learning, which is especially suitable for the initial screening of drugs, such as brain enhancement, memory improvement, anti-aging and other nervous system care. The Step-Down device adopts microcomputer control and to be well distinguished the rodent step down. Researcher set the test time and the controller record the incorrect times and the step-down latency, the retention latency is to be measured as aversive learning and memory. The longer the retention latency, the better the memory.

Overview

Step-Down Avoidance Task

The Rodent Step-Down Avoidance Task is widely used in observing the effects of drugs on memory and learning, which is especially suitable for the initial screening of drugs, such as brain enhancement, memory improvement, anti-aging and other nervous system care. The Step-Down device adopts microcomputer control and to be well distinguished the rodent step down. Researcher set the test time and the controller record the incorrect times and the step-down latency, the retention latency is to be measured as aversive learning and memory. The longer the retention latency, the better the memory.

Specification

Detailed Information

Technical Specifications

  • Applicable for both Rats and Mice.
  • Step-down chamber: 6 animals can be tested at the same time (3 rats and 6 mice).
  • Electric Stimulation: 0-5 mA adjustable.
  • Software: Incorrect times and latency.
  • 7-inch capacitive touch screen, friendly interface, clear display and simple operation.
  • Micro-printer integrated, automatic printing results (more suitable for pharmaceutical company).
  • Each channel independently timing, automatic start/finish.
  • Data exportable for convenient statistical analysis.
  • Controller size: 220×220×310mm (L*W*H), weight: 6kg.

Rat

  • Chambers: 950x300x360mm (Outer Size)
  • Activity inner box size: 300x300x300mm;
  • Platform: diameter: 90mm, height: 50mm

Mouse

  • Chambers: 900x200x360mm (Outer Size)
  • Activity inner box size:150x150x300mm
  • Platform: diameter: 40mm, height: 50mm.
  • Power input: AC220V 50/60HZ, power: 24W
Reference

Step-down Task Reference

Donepezil attenuates vascular dementia in rats through increasing BDNF induced by reducing HDAC6 nuclear translocation

Acta Pharmacologica Sinica

How to Order

Ordering Information

Item No. Product
SA202R Step-Down Avoidance Task for Rat
SA202M Step-Down Avoidance Task for Mouse

Start Now

Quality First, Cost Effective, Reputation Above All.

form-background

    Message *