Lab Animal Equipment
Lab Animal Equipment
  • Hot Plate
  • Hot Plate

Hot Plate

The hot plate test has been the gold standard test for thermal pain tests in rodents and acts as an effective screening tool interventions of analgesia. Science Hot Plate adopt precise PID control algorithm, which is different from the temperature breakpoint method adopted by ordinary temperature controllers. The PID algorithm will continuously collect temperature feedback to control heating, thus being able to control the current temperature more accurately. The Hot Plate contains a metal temperature plate with a digital display and a lidded transparent glass cylindrical restrainer.

Overview

Hot Plate

The hot plate test has been the gold standard test for thermal pain tests in rodents and acts as an effective screening tool interventions of analgesia. Science Hot Plate adopt precise PID control algorithm, which is different from the temperature breakpoint method adopted by ordinary temperature controllers. The PID algorithm will continuously collect temperature feedback to control heating, thus being able to control the current temperature more accurately. The Hot Plate contains a metal temperature plate with a digital display and a lidded transparent glass cylindrical restrainer.

Features

The experimental temperature of placement of the subject on the plate and the first sign of nocifensive response such as paw licking or jumping can be recorded in real time.

  • Suitable for rats, mice, guinea pigs.
  • Experiment mode: constant temperature mode, variable temperature mode.
  • Adopts high-performance 32-bit microcomputer control chip to ensure the accurate temperature.
Specification

Detailed Information

Temperature

  • Temperature display mode: Capacitive eight-inch LCD display, resolution: 800×600
  • Temperature Range: 20°C-65°C, adjustment step 0.01°C
  • Temperature control standard deviation: <± 0.2 °C
  • Heating time: 1 minutes (from 20°C to 65°C when the ambient temperature is 20°C)

Time Display

  • Time display: 0.01~600.00s, Precision: 0.01 seconds
  • Time Display standard deviation: <0.02 %

Experimental Data

  • Experimental data: previous experimental curves and data can be viewed on the menu and each set of experimental data is displayed in real time: time, temperature, mean, maximum value, minimum value.
  • 100 group data can be stored, and each group can record 10 time data and instantaneous temperature data.
  • Data extraction from the Hot Plate test is straightforward by using a USB drive, in CSV format.

Size

  • Apparatus size: (L) 35 cm x (W) 30 cm x (H) 48.5 cm
  • Cylindrical restrainer dimensions: (D) 21cm x (H) 25 cm
  • Weight: 8 KG
  • Power requirement: 300W, 110/220V, 50-60HZ
How to Order

Order Information

Item No. Product Description
SA702 Hot Plate for Rat and Mouse